{"product_id":"mso2000x-flex-automotive-flexray-serial-bus-trigger-and-analysis","title":"MSO2000X-FLEX Automotive FlexRay Serial Bus Trigger and Analysis","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO2000X-FLEX adds FlexRay protocol triggering, decoding, and search to your MSO2000X Series oscilloscope. FlexRay is a deterministic, fault-tolerant bus for safety-critical chassis control, braking, and drive-by-wire applications.\u003c\/p\u003e\n\u003cp\u003eFlexRay provides dual-channel redundancy and guaranteed time slots for critical messages. This option overlays decoded protocol content on the physical signal for debugging timing and electrical issues simultaneously. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexRay Triggering\u003c\/strong\u003e — Trigger on frame ID, cycle count, payload data, indicator bits, null frames, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Frame Decoding\u003c\/strong\u003e — Decoded frames display with ID, payload, header CRC, and cycle info alongside the analog signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic\/Dynamic Segment Visibility\u003c\/strong\u003e — Identifies static vs. dynamic segment frames for schedule table verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Memory Search\u003c\/strong\u003e — Search acquisitions for specific frame IDs, data patterns, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Control Debug\u003c\/strong\u003e — Verify FlexRay timing in electronic suspension — trigger on static slots and check both protocol timing and signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Validation\u003c\/strong\u003e — Capture both Channel A and B to verify redundant message consistency and failover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all MSO2000X Series oscilloscopes: MSO2104X (100 MHz), MSO2204X (200 MHz), MSO2304X (300 MHz). The same capability is offered on other UNI-T oscilloscope families: MSO3000HD, MSO3000X, MSO5000HD, MSO7000X, MSO8000HD, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need FlexRay, the individual license covers exactly that protocol. The AUTO bundle adds the automotive protocols in one license. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":46595291578529,"sku":"191501400023","price":279.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5649\/2449\/files\/MSO2000X-FLEX.png?v=1782259504","url":"https:\/\/aaashopus.com\/products\/mso2000x-flex-automotive-flexray-serial-bus-trigger-and-analysis","provider":"SHOPSHOPSHOP","version":"1.0","type":"link"}