{"product_id":"ut196-solar-pro-trms-multimeter","title":"UT196 Solar Pro TRMS Multimeter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT196 is a True-RMS multimeter built for photovoltaic work, rated to 1700 V DC and 1500 V AC with CAT III 1000 V \/ CAT IV 600 V safety — the voltage headroom string and combiner measurements need. It's sealed to IP65 and survives a 2 m drop, with a dual display, analog bar graph, and built-in flashlight for rooftop and outdoor use.\u003c\/p\u003e\n\u003cp\u003eTrue-RMS reads AC accurately on distorted waveforms, a low-pass filter helps on inverter outputs, and an optional clamp sensor extends AC current measurement to 3000 A. Non-contact voltage detection, resistance to 60 MΩ, and capacitance to 60 mF round out the field set. It's backed by UNI-T's nearly 40 years of test-meter manufacturing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRated 1700 V DC \/ 1500 V AC for PV strings and combiners\u003c\/li\u003e\n\u003cli\u003eTrue-RMS measurement with dual display and analog bar graph\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eIP65 sealing and 2 m drop protection\u003c\/li\u003e\n\u003cli\u003eAC current to 3000 A with optional clamp sensor\u003c\/li\u003e\n\u003cli\u003eLow-pass filter (LPF) for inverter outputs\u003c\/li\u003e\n\u003cli\u003eNon-contact voltage (NCV) detection\u003c\/li\u003e\n\u003cli\u003eResistance to 60 MΩ; capacitance to 60 mF; built-in flashlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT196 Details\u003c\/h2\u003e\n\u003ch3\u003eBuilt for PV Voltages\u003c\/h3\u003e\n\u003cp\u003ePhotovoltaic strings sit well above ordinary mains levels. The UT196 measures up to 1700 V DC and 1500 V AC, so string and combiner voltages stay on-scale and within the meter's safety rating.\u003c\/p\u003e\n\u003ch3\u003eTrue-RMS \u0026amp; Inverter Work\u003c\/h3\u003e\n\u003cp\u003eTrue-RMS sensing keeps AC accurate on the distorted waveforms around inverters, and a low-pass filter strips high-frequency content to read the fundamental on an inverter output.\u003c\/p\u003e\n\u003ch3\u003eField-Sealed Build\u003c\/h3\u003e\n\u003cp\u003eAn IP65-sealed body and 2 m drop rating handle rooftops and outdoor arrays, while a dual display, analog bar graph, and built-in flashlight keep readings clear in the field.\u003c\/p\u003e\n\u003ch3\u003eExtended Current \u0026amp; Safety\u003c\/h3\u003e\n\u003cp\u003eAn optional clamp sensor extends AC current measurement to 3000 A for string and feeder work, and non-contact voltage detection flags live conductors before you probe.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eSolar PV installation and commissioning; string, combiner, and inverter measurement; rooftop and ground-mount maintenance; and outdoor electrical work where high DC voltage, sealing, and drop resistance matter.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhy does the UT196 measure to 1700 V DC?\u003c\/h3\u003e\n\u003cp\u003ePhotovoltaic strings operate well above ordinary mains voltage; the 1700 V DC range keeps string and combiner measurements within the meter's safety rating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eIs it suitable for outdoor use?\u003c\/h3\u003e\n\u003cp\u003eYes — it is IP65-sealed, rated for a 2 m drop, and has a built-in flashlight for low-light work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eCan it measure high current?\u003c\/h3\u003e\n\u003cp\u003eYes — AC current up to 3000 A with an optional clamp sensor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1700 V, ±(0.2% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V, ±(0.8% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Current (with clamp sensor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 3000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MHz, ±(0.08% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 MΩ, ±(0.8% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mF, ±(1.9% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDual Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-Pass Filter (LPF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNCV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bar Graph\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Power Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlashlight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT196%20Data%20Sheet.pdf\"\u003eUT196 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT196_User_Manual.pdf\"\u003eUT196 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":46595285287073,"sku":"180100190590X","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5649\/2449\/files\/UT196_1.png?v=1782259435","url":"https:\/\/aaashopus.com\/products\/ut196-solar-pro-trms-multimeter","provider":"SHOPSHOPSHOP","version":"1.0","type":"link"}