{"product_id":"ute323-3-ch-high-precision-digital-power-meter","title":"UTE323 3-Ch High-Precision Digital Power Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTE323 Series\u003c\/strong\u003e is a three-channel high-precision digital power meter for three-phase and multi-rail power measurement. Three synchronized measurement channels capture a full three-phase system — or three independent DC\/AC rails — in one instrument, with per-channel and total power, power factor, frequency, energy and harmonics.\u003c\/p\u003e\n\u003cp\u003eIt samples at 300 kSa\/s across a DC to 300 kHz bandwidth and supports every standard wiring configuration (1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A). The UTE323 communicates over RS-232; the UTE323G substitutes GPIB for instrument-bus racks. Measurement firmware and accuracy are identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTE323 Series\u003c\/h2\u003e\n\u003cp\u003eTwo models, one platform. They differ only by communication interface — channel count, accuracy, 300 kSa\/s sampling, wiring modes and harmonic analysis are identical:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:40%\"\u003e\n\u003ccol style=\"width:26%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003cth\u003eWiring Modes\u003c\/th\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323G\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ \u003cstrong\u003eGPIB\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose by the interface your test bench uses.\u003c\/p\u003e\n\u003cp\u003eNeed single-phase high-voltage measurement, or a compact panel meter? See the single-channel UTE310 Series (600 V \/ 1000 V single-phase) or the UTE9800+ Series compact power meters — distinct instrument lines for different measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003eThree synchronized measurement channels — full three-phase or three independent rails\u003c\/li\u003e\n\u003cli\u003eWiring modes: 1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/li\u003e\n\u003cli\u003e300 kSa\/s synchronous sampling on all channels\u003c\/li\u003e\n\u003cli\u003eDC to 300 kHz measurement bandwidth\u003c\/li\u003e\n\u003cli\u003ePer-channel and total power, PF, frequency and energy\u003c\/li\u003e\n\u003cli\u003eHarmonic analysis to the 50th order, per channel\u003c\/li\u003e\n\u003cli\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/li\u003e\n\u003cli\u003e5-inch TFT-LCD with simultaneous waveform display\u003c\/li\u003e\n\u003cli\u003eD\/A analog output for external recording\u003c\/li\u003e\n\u003cli\u003eRS-232 standard; GPIB on UTE323G in its place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTE323 Series Details\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eUTE323 multi-parameter measurement display\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eThree-Phase \u0026amp; Multi-Rail Wiring Modes\u003c\/h3\u003e\n\u003cp\u003eThe UTE323 supports every standard configuration — single-phase two\/three-wire, three-phase three\/four-wire and the 3V3A method. One instrument measures a complete three-phase inverter output, a three-rail DC bus or three independent converters without re-cabling between standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eUTE323 multi-parameter measurement display\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSynchronous 300 kSa\/s Multi-Channel Sampling\u003c\/h3\u003e\n\u003cp\u003eAll three channels sample synchronously at 300 kSa\/s, so phase relationships and per-phase power are measured against a common time base — essential for true three-phase power and imbalance measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDC to 300 kHz Wide-Bandwidth Measurement\u003c\/h3\u003e\n\u003cp\u003eThe wide DC–300 kHz bandwidth keeps switching content and harmonics in the per-phase power calculation, so three-phase inverter and drive measurements reflect the real waveform rather than the fundamental alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\"\u003e\u003cspan class=\"lightbox-caption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePer-Channel Harmonic Analysis\u003c\/h3\u003e\n\u003cp\u003eHarmonic analysis to the 50th order runs on each channel independently, quantifying per-phase distortion on three-phase rectifier and drive front ends.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePer-Channel Energy Integration\u003c\/h3\u003e\n\u003cp\u003eWatt-hour and amp-hour integration accumulate per channel for three-phase efficiency runs and long-duration multi-rail energy profiling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSimultaneous Waveform Display\u003c\/h3\u003e\n\u003cp\u003eThe 5-inch display shows all channel waveforms together, confirming phase rotation and wiring before the measurement is trusted.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eSimultaneous waveform display across channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003eSimultaneous waveform display across channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eD\/A analog output for external recording\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eD\/A Output\u003c\/h3\u003e\n\u003cp\u003eA D\/A analog output drives a chart recorder or DAQ for long-term trend logging of any measured channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\"\u003e\u003cspan class=\"lightbox-caption\"\u003eD\/A analog output for external recording\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eGPIB in Place of RS-232 — UTE323G\u003c\/h3\u003e\n\u003cp\u003eThe UTE323G substitutes a GPIB (IEEE-488) port for RS-232 — it does not add GPIB alongside it. USB and LAN are present on both models, so if you automate over LAN the base UTE323 already covers you; the UTE323G is for racks built on a GPIB instrument bus.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eThree-Phase Inverter \u0026amp; Motor-Drive Efficiency\u003c\/h3\u003e\n\u003cp\u003eMeasure three-phase output power and per-phase imbalance on inverter and motor-drive designs in a single instrument, with synchronous sampling that holds phase relationships true.\u003c\/p\u003e\n\u003ch3\u003eMulti-Rail \u0026amp; Multi-Converter Test\u003c\/h3\u003e\n\u003cp\u003eThree independent channels measure three DC\/AC rails or three converters at once — one instrument instead of three single-channel meters on a multi-output power-electronics bench.\u003c\/p\u003e\n\u003ch3\u003eProduction \u0026amp; QA Test Bench\u003c\/h3\u003e\n\u003cp\u003ePer-channel limits, energy integration and a single RS-232\/GPIB or LAN connection make the UTE323 a compact end-of-line and QA power-test station for small test labs and consultancies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eUTE-series test cables support safe three-phase connection. Pair the UTE323 with UNI-T programmable sources and electronic loads for a complete three-phase power-characterization bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan the UTE323 measure a full three-phase system at once?\u003c\/h3\u003e\n\u003cp\u003eYes. Three synchronized channels and the 3P3W \/ 3P4W \/ 3V3A wiring modes measure a complete three-phase system in one instrument.\u003c\/p\u003e\n\u003ch3\u003eCan the three channels measure independent rails instead of one three-phase system?\u003c\/h3\u003e\n\u003cp\u003eYes. The three channels can measure three independent DC\/AC rails or converters simultaneously.\u003c\/p\u003e\n\u003ch3\u003eDoes the UTE323G add GPIB on top of RS-232?\u003c\/h3\u003e\n\u003cp\u003eNo — it substitutes GPIB for RS-232. USB and LAN are on both models; the UTE323G is for GPIB-bus racks.\u003c\/p\u003e\n\u003ch3\u003eDoes each channel measure harmonics?\u003c\/h3\u003e\n\u003cp\u003eYes — per-channel harmonic analysis to the 50th order.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTE323 \/ UTE323G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (synchronous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75mV – 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5W – 12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300kSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC, 0.1Hz – 300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st – 50th\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-inch TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=116\"\u003eUTE323 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BB x3\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BU x3\u003c\/li\u003e\n  \u003cli\u003eRed\/Black termals x6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":46595302916257,"sku":"182700300017X","price":3699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5649\/2449\/files\/UTE323_1_sq_c9470071-6889-495f-b929-68064c2f28ac.jpg?v=1782259808","url":"https:\/\/aaashopus.com\/products\/ute323-3-ch-high-precision-digital-power-meter","provider":"SHOPSHOPSHOP","version":"1.0","type":"link"}