{"product_id":"uts3000a-emi-emi-pre-compliance-measurement-option","title":"UTS3000A-EMI EMI Pre-Compliance Measurement Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UTS3000A-EMI adds EMI pre-compliance measurement — quasi-peak detectors, limit lines (CISPR, FCC, EN, MIL-STD-461, VCCI), automated scans, and pass\/fail reporting. Catch failures early and save weeks of redesign. The option is enabled by a software license keyed to the spectrum analyzer's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Detectors\u003c\/strong\u003e — Quasi-peak, EMI average, peak, negative peak per CISPR 16.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit Lines\u003c\/strong\u003e — CISPR 11\/22\/32, FCC Part 15, EN 55011\/55032, MIL-STD-461, VCCI, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Scans\u003c\/strong\u003e — Scan-search-measure workflows — peaks identified, quasi-peak measured, results compiled automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePass\/Fail Reports\u003c\/strong\u003e — On-instrument compliance reports with margin analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePair with UTS-EMI01\u003c\/strong\u003e — Combine with UTS-EMI01 near-field probes to locate emission sources on PCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Compliance\u003c\/strong\u003e — Run EMI scans with FCC\/CISPR limits during prototyping — find issues before the compliance lab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFailed Test Troubleshooting\u003c\/strong\u003e — Reproduce compliance failures on your bench, iterate on filter designs, measure improvements in real time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all UTS3000A Series spectrum analyzers: UTS3015A (1.5 GHz), UTS3026A (2.6 GHz), UTS3036A (3.6 GHz), UTS3046A (4.5 GHz). The same capability is offered on other UNI-T spectrum analyzer families: UTS1000B, UTS3000B, UTS5000A, UTS7000A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs this sufficient for formal compliance?\u003c\/h3\u003e\n\u003cp\u003ePre-compliance screening — catches most issues early. Formal testing requires a certified lab with calibrated antennas and chambers.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the spectrum analyzer's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the spectrum analyzer from a USB drive through the option-install menu. Refer to the spectrum analyzer's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":46595294691489,"sku":"191500100004","price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5649\/2449\/files\/UTS3000A-EMI_e1a7a695-7131-4fab-a9a5-379738bc2b5f.png?v=1782259562","url":"https:\/\/aaashopus.com\/products\/uts3000a-emi-emi-pre-compliance-measurement-option","provider":"SHOPSHOPSHOP","version":"1.0","type":"link"}