{"product_id":"uts7000a-amk-advanced-measurement-kit-option","title":"UTS7000A-AMK Advanced Measurement Kit Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e\u003cstrong\u003eUTS7000A-AMK\u003c\/strong\u003e is the advanced measurement kit software-license option for the UTS7000A signal analyzer platform. The license adds a set of one-touch power and spectral measurements for routine RF characterization work — third-order intermodulation (TOI), occupied bandwidth (OBW), channel power, adjacent-channel power ratio (ACPR), carrier-to-noise ratio (CNR), harmonic analysis, time-domain power, and spectrum monitoring with waterfall plot.\u003c\/p\u003e\n\u003cp\u003eEach measurement is presented as a dedicated measurement screen rather than as a manual sequence of marker placements. The license is purchased against the chassis serial number, installed via the chassis Option Install menu, and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Power measurement\u003c\/strong\u003e — Channel power and power integral density\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT-power (time-domain power)\u003c\/strong\u003e — Zero-sweep time-integral power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOccupied Bandwidth (OBW)\u003c\/strong\u003e — Occupancy power and transmission frequency error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjacent Channel Power (ACPR)\u003c\/strong\u003e — Main channel power, left and right adjacent channel power and power ratio\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier-to-Noise Ratio (CNR)\u003c\/strong\u003e — Carrier power and noise power outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird Order Intermodulation (TOI)\u003c\/strong\u003e — Automatic search based on dual-tone peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic analysis\u003c\/strong\u003e — Up to 10 harmonics maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrum monitoring with waterfall plot\u003c\/strong\u003e — Long-duration spectrum capture with time history\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhat Advanced Measurement Kit Adds\u003c\/h2\u003e\n\u003cp\u003eThe AMK option configures the instrument with dedicated power-suite and nonlinear-measurement screens. Specifications are taken from the UTS7000A Series datasheet.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:42%\"\u003e\n\u003ccol style=\"width:58%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Power outputs\u003c\/td\u003e\n\u003ctd\u003eChannel power, power integral density\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-power outputs\u003c\/td\u003e\n\u003ctd\u003eZero-sweep time-integral power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOccupied Bandwidth outputs\u003c\/td\u003e\n\u003ctd\u003eOccupancy power, transmission frequency error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent Channel Power outputs\u003c\/td\u003e\n\u003ctd\u003eMain channel power, left adjacent channel power and ratio, right adjacent channel power and ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier-to-Noise Ratio outputs\u003c\/td\u003e\n\u003ctd\u003eCarrier power, noise power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThird Order Intermodulation method\u003c\/td\u003e\n\u003ctd\u003eAutomatic search based on dual-tone peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic analysis maximum\u003c\/td\u003e\n\u003ctd\u003e10 harmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectrum monitoring display\u003c\/td\u003e\n\u003ctd\u003eWaterfall plot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating mode\u003c\/td\u003e\n\u003ctd\u003eDedicated measurement screens accessible from the chassis option menu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following measurement workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduction-floor RF characterization\u003c\/strong\u003e — One-touch channel power, ACPR, and OBW measurements for repeatable per-unit verification on manufacturing test stations, replacing manual marker-placement sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter spectral compliance\u003c\/strong\u003e — ACPR, OBW, and TOI measurements for transmitter pre-compliance to spectral-mask requirements before scheduled regulatory testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReceiver and amplifier linearity characterization\u003c\/strong\u003e — Two-tone TOI measurement for third-order intercept point on RF amplifiers, mixers, and complete receiver front ends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-duration spectrum monitoring\u003c\/strong\u003e — Waterfall-plot spectrum monitoring for intermittent signal capture, interference characterization, and frequency-occupancy studies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic distortion characterization\u003c\/strong\u003e — Up to 10-harmonic analysis for transmitter and amplifier harmonic-distortion qualification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThe option installs as a software license on any UTS7000A series chassis. Compatibility:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eChassis variant\u003c\/th\u003e\n\u003cth\u003eOption install\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" class=\"cohort-label\"\u003e\u003cstrong\u003eUTS7000A — Wide-Band Configuration (40 MHz baseline)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7013A — 2 Hz to 13.6 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7026A — 2 Hz to 26.5 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7032A — 2 Hz to 32 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7040A — 2 Hz to 40 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" class=\"cohort-label\"\u003e\u003cstrong\u003eUTS7000A–NB — Narrow-Band Configuration (20 MHz fixed)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7013A–NB — 2 Hz to 13.6 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7026A–NB — 2 Hz to 26.5 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7032A–NB — 2 Hz to 32 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7040A–NB — 2 Hz to 40 GHz\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eAre the AMK measurements available as one-touch screens or as marker sequences?\u003c\/h3\u003e\n\u003cp\u003eEach measurement in the AMK option is presented as a dedicated measurement screen with standing numeric and graphical readouts. The screens replace the manual marker-placement workflow that the same measurements would require on the base spectrum-analyzer mode.\u003c\/p\u003e\n\u003ch3\u003eDoes AMK include modulation analysis (EVM, constellation)?\u003c\/h3\u003e\n\u003cp\u003eNo. AMK covers power, spectral occupancy, and nonlinear measurements. For modulation analysis with constellation and EVM, the UTS7000A-VSA (general-purpose digital modulation), UTS7000A-FDD-LTE, UTS7000A-TDD-LTE, and UTS7000A-NR options cover the respective modulation-analysis use cases.\u003c\/p\u003e\n\u003ch3\u003eHow is the license installed?\u003c\/h3\u003e\n\u003cp\u003eThe license is purchased against the chassis serial number, registered on the UNI-T website to obtain the license file, and installed via the chassis Option Install menu using a USB storage device. Refer to the chassis User Manual for the full step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that remains active for the life of the instrument. There are no subscription fees, no annual renewals, and no expiration date.\u003c\/p\u003e\n\u003ch3\u003eCan the option be installed on a UTS7000A–NB narrow-band chassis?\u003c\/h3\u003e\n\u003cp\u003eYes. Measurement function options install on all UTS7000A chassis variants including the narrow-band (–NB) configurations. The option installs and operates independently of the chassis bandwidth configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=117\"\u003eUTS7000A-AMK Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":46595301834913,"sku":"191501600005","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5649\/2449\/files\/UTS7000A-AMK_2992f96e-2cf3-4b2f-92d4-1c00f7a2cc3b.png?v=1782259750","url":"https:\/\/aaashopus.com\/products\/uts7000a-amk-advanced-measurement-kit-option","provider":"SHOPSHOPSHOP","version":"1.0","type":"link"}