{"product_id":"uts7000a-b85-85-mhz-real-time-analysis-bandwidth-license","title":"UTS7000A-B85 85 MHz Real-Time Analysis Bandwidth License","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS7000A-B85\u003c\/strong\u003e is the software-license option that expands the UTS7000A series real-time analysis bandwidth from the 40 MHz baseline to 85 MHz. Every US-market UTS7000A chassis (UTS7013A, UTS7026A, UTS7032A, and UTS7040A) ships pre-calibrated to the 40 MHz baseline. The B85 license unlocks the wider bandwidth path on the same chassis — no return-to-factory, no hardware change.\u003c\/p\u003e\n\u003cp\u003eThe expansion applies to both real-time spectrum analysis and I\/Q capture, and lifts the maximum sampling rate to 1 GSa\/s. The license is purchased against the chassis serial number, installed via the chassis Option Install menu, and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e85 MHz real-time analysis bandwidth\u003c\/strong\u003e — Expands RTSA and I\/Q analysis from the 40 MHz baseline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 GSa\/s sampling on the wide-band IF path\u003c\/strong\u003e — Up from 100 MSa\/s on the 20 MHz baseline path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep in the upgrade path\u003c\/strong\u003e — The B85 path can later be replaced by the wider UTS7000A-B160 (160 MHz) or UTS7000A-B255 (255 MHz) licenses on the same chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhat Changes With B85 Installed\u003c\/h2\u003e\n\u003cp\u003eThe following specifications shift from the 40 MHz baseline to the 85 MHz path when the B85 license is active. Values are taken directly from the UTS7000A Series datasheet.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:40%\"\u003e\n\u003ccol style=\"width:30%\"\u003e\n\u003ccol style=\"width:30%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e40 MHz Baseline\u003c\/th\u003e\n\u003cth\u003eWith B85 Installed\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/Q analysis frequency-sweep width\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 40 MHz\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 85 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTSA analysis bandwidth\u003c\/td\u003e\n\u003ctd\u003e5 kHz to 40 MHz\u003c\/td\u003e\n\u003ctd\u003e5 kHz to 85 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax sampling rate\u003c\/td\u003e\n\u003ctd\u003e100 MSa\/s (20 MHz baseline path); 1 GSa\/s (40 MHz path)\u003c\/td\u003e\n\u003ctd\u003e1 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/Q data rate\u003c\/td\u003e\n\u003ctd\u003eIFBW × 1.25 (20 MHz path); IFBW × 1.2 (40 MHz path)\u003c\/td\u003e\n\u003ctd\u003eIFBW × 1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. signal duration for 100% POI at RBW6 (Kaiser, 85 MHz span)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e3.24 μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. RBW at 85 MHz span (Kaiser window)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e294.0028 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. RBW at 85 MHz span (Kaiser window)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e9.4669 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC resolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003ctd\u003e14 bits (unchanged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe B85 license is appropriate when measurements need real-time capture or wider I\/Q analysis beyond the 40 MHz baseline. Typical workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWideband modulated signal capture\u003c\/strong\u003e — Signals with instantaneous bandwidth between 40 and 85 MHz that exceed the baseline capture window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5G NR component carriers\u003c\/strong\u003e — Carriers with 50, 60, 70, or 80 MHz system bandwidth in FR1, captured in a single record without segmented acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency-hopping and pulsed signals\u003c\/strong\u003e — Wider real-time bandwidth raises the probability of intercept for short-duration events that fall outside the baseline 40 MHz window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWideband I\/Q records for offline analysis\u003c\/strong\u003e — 8,000,000 IQ sample pairs at 1 GSa\/s sample rate for vector-signal-analysis post-processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor instantaneous bandwidth requirements beyond 85 MHz, the UTS7000A-B160 (160 MHz) and UTS7000A-B255 (255 MHz) licenses extend the same path further; both install on the same 40 MHz-baseline chassis the B85 targets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThe UTS7000A-B85 is a software license installed on a UTS7000A chassis. Compatibility is determined by chassis variant:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:50%\"\u003e\n\u003ccol style=\"width:50%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eChassis variant\u003c\/th\u003e\n\u003cth\u003eB85 license install\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7013A (40 MHz baseline)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7026A (40 MHz baseline)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7032A (40 MHz baseline)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7040A (40 MHz baseline)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS7000A–NB narrow-band variants (20 MHz fixed)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNot supported\u003c\/strong\u003e — the narrow-band chassis hardware does not accept B-series licenses.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs the UTS7000A-B85 a software license or a hardware option?\u003c\/h3\u003e\n\u003cp\u003eIt is a software license. Every US-market UTS7000A chassis ships pre-calibrated to the 40 MHz baseline at the factory; the B85 expansion is unlocked field-side on the existing chassis via a license file. No return-to-factory and no hardware change are required.\u003c\/p\u003e\n\u003ch3\u003eHow is the license installed?\u003c\/h3\u003e\n\u003cp\u003eThe license is purchased against the chassis serial number, registered on the UNI-T website to obtain the license file, and installed via the chassis Option Install menu using a USB storage device. Refer to the chassis User Manual for the full step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that remains active for the life of the instrument. There are no subscription fees, no annual renewals, and no expiration date.\u003c\/p\u003e\n\u003ch3\u003eCan the B85 license be installed on a UTS7000A–NB chassis?\u003c\/h3\u003e\n\u003cp\u003eNo. The narrow-band (–NB) chassis variants are fixed at 20 MHz real-time bandwidth with no upgrade path. B-series licenses install only on the 40 MHz-baseline wide-band variants (UTS7013A, UTS7026A, UTS7032A, UTS7040A).\u003c\/p\u003e\n\u003ch3\u003eCan I upgrade later from B85 to B160 or B255?\u003c\/h3\u003e\n\u003cp\u003eYes. The B85, B160, and B255 licenses are sold as separate purchases against the same chassis. Customers who later need wider bandwidth purchase the higher-tier license against the same chassis serial number. Consult UNI-T sales for license-upgrade specifics on a chassis that already has B85 installed.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=117\"\u003eUTS7000A-B85 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":46595301245089,"sku":"191502400028","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/5649\/2449\/files\/UTS7000A-B85_950bdab4-dc6c-4317-9f68-e9aaf06ab705.png?v=1782259742","url":"https:\/\/aaashopus.com\/products\/uts7000a-b85-85-mhz-real-time-analysis-bandwidth-license","provider":"SHOPSHOPSHOP","version":"1.0","type":"link"}