← 返回
跳至产品信息
1 / 15

UT281F True RMS Flex Clamp Sensor

UT281F True RMS Flex Clamp Sensor

常规价格 $275.00 USD
常规价格 促销价 $275.00 USD
促销 售罄

Overview

The UT281F pairs a flexible 1100 mm coil with power measurement: it reads AC current up to 10 kA on large or awkward conductors and, beyond current, measures active, apparent, and reactive power with power factor and phase angle — so you can assess load behaviour on a big feeder, not just its current. It's rated CAT III 1000 V / CAT IV 600 V.

True-RMS sensing, a dual display, Bluetooth 5.0 for transfer, and storage for 1050 result sets make it a documentation-ready tool for utility and industrial power work. It's backed by UNI-T's nearly 40 years of test-meter manufacturing.

Key Features

  • Flexible 1100 mm coil for large and awkward conductors
  • AC current up to 10 kA (45 Hz–1000 Hz)
  • Power measurement: active, apparent, reactive, with power factor and phase angle
  • True-RMS measurement; dual display
  • AC/DC voltage to 1000 V; resistance to 60 MΩ; continuity
  • Bluetooth 5.0 for data transfer; 1050-set storage
  • CAT III 1000 V / CAT IV 600 V; AA battery power

UT281F Details

Flexible-Coil High-Current Measurement

The 1100 mm flexible coil wraps around busbars, cable bundles, and large conductors a rigid clamp can't reach, measuring AC current up to 10 kA across a 45 Hz–1000 Hz band.

Power, Not Just Current

Beyond current, the UT281F measures active, apparent, and reactive power with power factor and phase angle — so you can see how a feeder is actually loaded and where reactive power and poor power factor are costing capacity.

Documentation-Ready

True-RMS sensing on a dual display, Bluetooth 5.0 transfer, and storage for 1050 result sets make it straightforward to capture and move power readings for reports and load studies.

Compare the UT281 Series

UT281E+ UT281F
Max AC current 9.99 kA 10 kA
Inrush current Yes
Power measurement Active / apparent / reactive, PF, phase
Connectivity Bluetooth 5.0
Data storage 999 sets 1050 sets
Jaw opening 1000 mm 1100 mm

Applications

Feeder and busbar power studies; load and power-factor assessment on large industrial and utility circuits; high-current measurement on conductors a clamp can't reach; and maintenance work that needs power figures documented.

Frequently Asked Questions

What does the UT281F measure beyond current?

Active, apparent, and reactive power, with power factor and phase angle.

How large a conductor can it measure?

Its 1100 mm flexible coil wraps around large busbars and cable bundles; AC current measures up to 10 kA.

How is it different from the UT281E+?

The UT281E+ measures current with inrush capture; the UT281F adds full power measurement and Bluetooth 5.0 transfer.

Specifications

DC Voltage In 1000 V
AC Voltage In 1000 V
AC Current In 10 kA
AC Current Frequency 45 Hz to 1000 Hz
Frequency Range 10 Hz to 30 kHz
Internal Resistance Range 60 MΩ
Max Resistance 60 MΩ
Power Factor -1 to 1
Phase Angle -360°–360°
True RMS Yes
Continuity Yes
Dual Display Yes
Data Communication BT 5.0
Data Storage 1050 sets
CAT Rating CAT III 1000 V , CAT IV 600 V
Jaw Opening 1100 mm
Display Type Dual LCD
Battery 3× AA
Ambient Temperature Range 0 °C to 40 °C
Frequency Response 50 Hz to 500 Hz
数量

低库存:剩余 10

查看完整详细信息